| General |
|
| PoLiFlex Cell PLF383562 incl.
safety circuit |
| Weight: |
appr. 20g |
| PCM: |
EAP 750 |
|
| Electrical Specification |
|
| Rated Capacity: |
720 mAh min. 750 mAh typ. (at
0.2C from 4.2V 3.0V at 20°C) |
| Nominal Voltage: |
3.7V |
| Max. Operating Voltage Range: |
2.75V to 4.2V |
| Charging Method: |
Constant current +
Constant voltage |
| Charge Voltage [V]: |
4.20 (±50mV) |
| Initial charge current [mA]: |
Standard Charge:
360
Rapid Charge: 720 |
Charging cut-off [a)
or b)] |
|
| a) by time [h] |
Standard Charge: 5
Rapid Charge: 3 |
| b) by min. current [mA]: |
14 |
| Max. Continuous Discharge Current: |
1440 mA |
| Initial Impedance (1kHz): |
120 mOhm |
| Exp. Cycle Life: |
>500 cycles >70% of initial
cap. (0.5C/0.5C) ID = 6.8kOhm ±1%,
NTC = 10kOhm ±3%,
B-Value 3435K ±3% |
|
| Cell Protection: |
|
| Overcharge Detection: |
max. 4.35V
(max. 2sec. delay, resume min. 4.0V) |
| Overdischarge Detection: |
min. 2.2V
(max. 250msec. delay, resume by charge) |
| Overcurrent Detection: |
3.0A to 5.5A (4
to 16 msec. delay) |
|
| Ambient Conditions |
|
| Temperature Range |
|
| -Charge: |
0 to +45°C |
| -Discharge: |
-20 to + 60°C |
| - Charge Retention/Storage
[%]: |
1 year at -20 to
20°C >70
3 month at -20 to 45°C >70
1 month at -20 to 60°C
>70 |
| Humidity: |
65 ± 20%RH |
|
| Safety |
|
| Please follow Handling and Safety
Precautions Poliflex |
| |
|