Cell Pack Solutions Ltd
Custom Made Cell Packs & Industrial Batteries

Click here to print this page print
EasyPack 2000
<BACK Download Datasheet Download Datasheet
Rechargeable EasyPack
Data Sheet
EASY PACK 2000



General  
PoLiFlex Cell 2P/PLF503562 incl. safety circuit
Weight: appr. 46.5g
PCM: EAP 2000

Electrical Specification  
Rated Capacity: 1910 mAh min. 2000 mAh typ. (at 0.2C from 4.2V 3.0V at 20°C)
Nominal Voltage: 3.7V
Max. Operating Voltage Range: 2.75V to 4.2V
Charging Method: Constant current +
Constant voltage
Charge Voltage [V]: 4.20 (±50mV)
Initial charge current [mA]: Standard Charge: 475
Rapid Charge: 955
Charging cut-off [a)
or b)]
 
a) by time [h] Standard Charge: 7
Rapid Charge: 4
b) by min. current [mA]: 38
Max. Continuous Discharge Current: 1910 mA
Initial Impedance (1kHz): 90 mOhm
Exp. Cycle Life: >300 cycles >70% of initial cap. (0.5C/0.5C) ID = 24kOhm ±1%,
NTC = 10kOhm ±3%,
B-Value 3435K ±3%

Cell Protection:  
Overcharge Detection: max. 4.35V
(max. 2sec. delay, resume min. 4.0V)
Overdischarge Detection: min. 2.2V
(max. 250msec. delay, resume by charge)
Overcurrent Detection: 3.0A to 5.5A (4 to 16 msec. delay)

Ambient Conditions  
Temperature Range  
-Charge: 0 to +45°C
-Discharge: -20 to + 60°C
- Charge Retention/Storage [%]: 1 year at -20 to 20°C >70
3 month at -20 to 45°C >70
1 month at -20 to 60°C
>70
Humidity: 65 ± 20%RH

Safety  
Please follow Handling and Safety Precautions Poliflex
   
 

Cell Pack Solutions Ltd - Unit 218 Tedco Business Works, South Shields, Tyne and Wear, NE33 1RF. UK.
Tel: +44 (0)191 4274577 - Fax: +44 (0)191 4274606 -
E-mail:
VAT No: 708 9179 02 - Company No: 4177772
www.cellpacksolutions.co.uk