There are a number of factors which must be considered when calculating the expected run time of a cell or battery; it is not simply down to taking the rated values of the battery and using standard electrical equations to work out run time. These parameters are outlined in our Choosing the right battery pack this section will outline the more specific mathematics which goes into the calculation of battery run time. Calculating the individual cell run time is fairly straight forward, if you can get access to a datasheet for that cell then that will give you information regarding discharge characteristics and you may be able to read the information straight from the datasheet; when dealing with a battery pack the process is more complex. The idea being to work with the electrical specifications for the pack and reduce it down using the pack properties to work out what is seen by each individual cell in the pack; then the cell datasheets can be used to calculate run time. Voltage When looking at NiMh and NiCd, cut-off voltage is generally rated at 0.9V - 1V per cell, this also applies to Alkaline cells (nominally rated at 1.5V). When dealing with packs, these values need to be multipled by the number of cells in the pack that are connected in series. For more information see the example at the bottom of th page. Current
The constant current drawn from the pack is the important value; each cell will have a maximum continuous discharge rating. The cell may also have a moximum pulse discharge current rating depending on the type of cell. These values must not be exceeded or the damage to the cell could be caused; this isn't the only consideration when designing a pack. The amount of drain current has an affect on the capacity of the battery, the rated capacity is rated against a specified discharge current. A general rule of thumb is the closer to the drain current is to the capacity, the less capacity that will be available to utilise, you may see use made of 'C rate' when charging and discharging are discussed. The C rate is the capacity rating of the battery and is used relative to the charge or discharge rate of the battery. This rate is represented as a fraction of this value, e.g. take a battery with a capacity of 2000mAh, 1C (or C) = 2000mA, 0.2C = 400mA, 3C = 6000mA. At each of these different C rates, the characteristics of the battery will change, a good cell datasheet will outline these characteristics. Again, these vales need to be traslated to a battery pack, so in order to work out the current drain seen at each cell, divide the total drain current by the number of cells which are connected in parallel. After you have worked out the Cut-off voltage and current drain for each cell, this can be matched to the characteristics on cell datasheets and approximate service life can be estimated. Apart from this there are further considerations as mentioned earlier such as storage characteristics, operational temperature and drain current characteristics all have a bearing on operational life.
A further point regarding the datasheets which are available for cells, the values stated and graphs showing various characteristics are under stringent lab test conditions, i.e. room temperature, specific current drain and cut-off voltage. They can only act as a guide as real life applications are often different and it is important to be aware of this. |