Cell Pack Solutions Ltd
Custom Made Cell Packs & Industrial Batteries
home about contact customer service batterytastic.co.uk

Ansmann - ANS2600 <BACK
Click here to print this page print Data sheet Download Data sheet
This product is now discontinued and is only available whilst stocks last!

nominal voltage: 1,2V  


max. charge voltage: 1,5V at standard charge
    (0,1C / 20°C)
capacity    
nominal : 2600mAh discharge at 0,2C
  >2100mAh discharge at 1C
minimum: 2300mAh discharge at 0,2C
    1,0V end discharge voltage
    ambient temperature 20°C
     
max. continuous    
discharge current: 2500mA ambient temperature
    20....50°C
     
charge charge current charge time
standard charge: 250mA 16hrs at 20°C
quick charge: 900mA 3,25hrs
fast charge: 2500mA 1,1hrs
     
recommended charge -dV: 5....10mV
termination control dT/dt: 0,8....1°C per min
parameters: TCO: 40...50°C
     
trickle charge current: 20....100mA (recommended)
     
continuous overcharge: <125mA no conspicuous deformation,
(less than 1 year)   no leakage
     
internal resistance: 30mOhms at 1000Hz,
    battery fully charged
     
life expectancy: >500 cycles IEC standard
     
ambient temperature range: 0....40°C standard charge
  0....40°C fast charge
  -20....65°C discharge
  -20....50°C storage less than 30 days
  -20....40°C storage less than 3 months
  -20....35°C storage less than 1 year

Standard Charge
Fast Charge (Charge Control required)
Low Rate Discharge
High Rate Discharge

mechanical specifications
cell dimensions (with sleeve)
diameter d1: 14,3-0,4mm
diameter d2: 5,5-0,5mm
height h1: 50,3-0,5mm
height h2: 1,6+/-0,3mm
weight: approx. 28g

 

Cell Pack Solutions Ltd - Unit 218 Tedco Business Works, South Shields, Tyne and Wear, NE33 1RF. UK.